0°C to 50°C operating
Storage -10°C to 55°C. Avoid rain and direct sunlight.
Specification V1.4
The full technical specification of the ZXTLCD-AIS007, plus the microphone diagrams and app screens from the source document.
This page reproduces specification V1.4 (issued 2026-07-03): display, touch, system, physical and environmental data, the AB microphone beam-angle diagrams, and the companion app screens that show how binding, records and AI minutes work. Where the source document states a range rather than a single value, the range is shown as published. Ask us before you commit to a figure that is not on this page.

2.1 Equipment parameters
Panel, loudspeaker, power and mechanical specification as published in section 2.1.
2.2 - 2.3 Touch and system
Touch parameters, operating system and interface configuration.

4. Microphone core algorithm
The AB microphone core algorithm separates the voices of two people speaking from different angles, correctly identifying which side of the translator each speaker belongs to. This is the beam layout the algorithm works from: beam1, beam2 and beam3 at both the 0-degree and 90-degree positions.
Opposing capture directions for the two sides of the desk.
Cross-axis capture used to confirm which side is speaking.

Voice separation
When the person on one side speaks, the array captures that side and suppresses the opposing loudspeaker direction, so the other party's voice does not leak into the translation. Both speakers' words are then displayed on their own screen and broadcast by voice output.
The speaking side is picked up by its own microphone channel.
The opposite channel is attenuated for that utterance.
Companion app screens
Screens from the source specification: the welcome and QR binding screen, account management, translation records, AI summary templates and device details.

Two QR codes: one to download Trans AI, one to bind the device to the signed-in account.

Bound accounts are listed with the current one marked; a new account can be added here.

A bilingual conversation log with each message kept in both languages.

Per-record summary with generate and delete actions.

Model, MAC address, software version, translation records and AI summary counts.

Choose a minutes template before generating the summary.
3. Usage environment
Section 3 of the specification states a narrower environmental envelope than section 2.1. This table shows section 3, which we treat as the governing value for site planning.
Storage -10°C to 55°C. Avoid rain and direct sunlight.
Both operating and storage humidity are specified as 20%-80% non-frosting.
Indoor use only; the working environment in section 2.1 is listed as indoor.
Next step
If your tender depends on a number that is not on this page, send it over and we will confirm in writing.
Specification query
Which figure, which deployment, and the deadline you are working to.